オートブレーカ・漏電遮断器

富士電機機器制御(株)のオートブレーカ・漏電遮断器総合カタログ
  • "33-15選定と適用 コンデンサ回路の選定電灯・電熱回路、溶接機回路、コンデンサ回路の選定■コンデンサ回路の選定●1φ コンデンサ設備容量に対する FAB(ELB)定格電流適用例定格周波数(Hz)定格電圧(V)定格設備容量(kvar)定格電流(A)定格コンデンサ容量定格直列リアクトル容量 6%FABELB定格電流(A)MC 形式(参考)(kvar) (μF) (kvar) (mH)502001.346.71.431000.096.0610SC-02.6713.42.842000.173.0420SC-4-03.3416.73.552500.212.4330SC-4-14.0120.14.273000.262.0330SC-5-1525.05.323740.321.6340SC-N11050.010.647480.640.8175SC-N2S1575.015.961,1220.960.54125SC-N420100.021.281,4961.280.41150SC-N625125.026.601,8701.600.33200SC-N730150.031.912,2441.910.27225SC-N840200.042.552,9922.550.20300SC-N1150250.053.193,7403.190.16400SC-N1275375.079.795,6104.790.11600SC-N14100500.0106.38 7,4806.380.08800SC-N16150750.0159.57 11,220 9.570.0512002001000.0 212.77 14,961 12.770.0415003001500.0 319.15 22,441 19.150.0325004001.072.71.14200.0730.385SC-031.604.01.70300.1020.3210SC-032.676.72.84500.1712.1810SC-04.0110.04.27750.268.1115SC-05512.55.32940.326.5020SC-4-01025.010.641870.643.2540SC-N11537.515.962810.962.1760SC-N22050.021.283741.281.6375SC-N2S2562.526.604681.601.30100SC-N33075.031.915611.911.08125SC-N440100.042.557482.550.81150SC-N650125.053.199353.190.65200SC-N775187.579.791,4034.790.43300SC-N11100250.0106.38 1,8706.380.33400SC-N14150375.0159.57 2,8059.570.22600SC-N16200500.0212.77 3,74012.770.16800SC-N16300750.0319.15 5,61019.150.111200602200.974.41.03500.0612.1710SC-031.948.82.061000.126.0815SC-02.9113.23.101500.194.0620SC-03.8817.64.132000.253.0430SC-4-1522.75.322580.322.3640SC-N11045.510.645150.641.1875SC-N2S1568.215.967730.960.79125SC-N42090.921.281,0301.280.59150SC-N625113.626.601,2881.600.47200SC-N730136.431.911,5461.910.39225SC-N840181.842.552,0612.550.30300SC-N1150227.353.192,5763.190.24400SC-N1175340.979.793,8644.790.16600SC-N14100454.5106.38 5,1526.380.12800SC-N14150681.8159.57 7,7289.570.081200200909.1212.77 10,303 12.770.0615003001363.6 319.15 15,455 19.150.0425004401.553.51.65200.1030.455SC-032.335.32.48300.1520.2610SC-03.117.13.31400.2015.1810SC-03.888.84.13500.2512.1715SC-4-0511.45.32640.329.4420SC-4-01022.710.641290.644.7240SC-N11534.115.961930.963.1560SC-N22045.521.282581.282.3675SC-N2S2556.826.603221.601.89100SC-N33068.231.913861.911.57125SC-N44090.942.555152.551.18150SC-N650113.653.196443.190.94175SC-N775170.579.799664.790.63300SC-N11100227.3106.38 1,2886.380.47350SC-N12150340.9159.57 1,9329.570.31600SC-N14200454.5212.77 2,57612.770.24700SC-N16300681.8319.15 3,86419.150.161000(備考 1)FAB(ELB)の定格電流はコンデンサの定格電流値の1.5 倍または投入後 0.01 秒の過渡突入電流実効値 + コンデンサ定格電流実効値の値の 10 分の 1 の値の大きい方の値を基準にしてその値の直近上位値から選定しています。(JISC4901 解説 IV. コンデンサ使用上の指針 d)より選定)(備考 2)自動力率調整など複数のコンデンサバンクの切換えを行う場合は別に電磁接触器を使用して開閉してください。また、直列リアクトルは必ず使用してください。この場合、主幹用遮断器の定格電流はコンデンサ容量の総和を求め、選定してください。 コンデンサ容量の総和値が上の表に無い場合は付録を参照して計算して選定してください。(備考 3)複数のコンデンサバンクを切替えて使用する場合、コンデンサからの過渡突入電流が大きいので計算によって電磁接触器を選定してください。(富士オートブレーカ、漏電遮断器技術資料EH150 参照)(備考 4)直列リアクトルはJISC4901「低圧進相コンデンサ」に従って 6% 値を標準に選定しています。 もし、高調波対策などで 8%、13% のものを使用する場合は計算してください。(技術資料 EH150 参照) --1/1-- "